Product Code |
HBWD100 |
HBWD120 |
Density |
100 |
120 |
Size(mm) |
1200×150;1200×200 |
|
Thickness(mm |
30-200 |
|
Remark |
Customized size and density are available |
Performance |
Unit |
HBWD100 |
HBWD120 |
Test Standard |
Tensile Strength (vertical to the surface) |
kPa |
≧150 |
≧200 |
GB/T 30804 |
Burning Behavior |
--- |
Class A1 non-combustible |
GB/T 8624-2012 |
|
Thermal Conductivity |
w/(m-k) |
≤0.045 |
GB/T-10294 |
|
Compressive Strength |
kPa |
--- |
GB/T 30805 |
|
Hydrophobic Rate |
% |
≧98 |
GB/T 10299 |
|
Moisture Absorption Rate |
% |
≤1.0 |
GB/T 5480 |
|
Dimensional Stability |
% |
≤0.5 |
GB/T 5480 |
|
Acidity Coefficient |
--- |
≧1.8 |
GB/T 5480 |
|
Executive Standard |
21.8 GB/T25975-2018 |
Hebang rockwool fire barriers are applicable to the foundation walls of reinforced concrete walls, concrete hollow block walls, and solid brick masonry walls(clay solid bricks are used for existing buildings only). They can be used as fire barriers matching with exterior wall heat preserving systems to improve the overall fire safety of the exterior walls of buildings and stop or delay the quick spreading of flames.
Hebang rockwool fire barriers are bonded with a strip adhesionmethod. In details, they are firmly pressed on foundation walls and then fixed by special anchors.